NORDAC ON / ON+ (SK 3xxP) – Manual with installation instructions
44 BU 0800 en-4521
LED Labelling Display Meaning
NS
ERROR = Ethernet Error
EtherCAT functioning normally on the bus interface
General EtherCAT configuration error
Bus interface has changed the EtherCAT state without authorisation
EtherCAT or FI time-out (P513, P151)
(Link activity)
Connection is established, data is being transmitted
Connection is established, no data transmission
3.1.2 Display of M1 and M2 when using EthernetIP
LED Labelling Display Meaning
(Link activity)
Connection is established, data is being transmitted
Connection is established, no data transmission
RUN
MS
MS = Module State
Off No mains or control voltage
Green On Bus interface working correctly
Green
flashing (4 Hz)
Bus interface not configured
Red
flashing (4 Hz)
Minor errors, faulty configuration
Red On Unrecoverable error
Red and Green
flashing
alternately (4 H
z)
Power-up, self test
NS
NS = Network State
No operating voltage, no IP address
flashing (4 Hz)
IP address configured but no CIP connection available
flashing (0.5 Hz
)
Frequency inverter is ready to switch-on, but not enabled
flashing (4 Hz)
Time-out, an "exclusive owner connection” has a time-out error
Dual IP. The IP address used by the bus interface is already in use
flashing
alternately (4 H
z)
(Link activity)
Connection is established, data is being transmitted
Connection is established, no data transmission