46 BU 0800 en-4521
3.1.5 Display of M4 and M5
LED Labelling Display Meaning
M4 – 1
DIN1
Yellow On
Digital input 1 = high
Off
Digital input 1 = low
Red On
Overload
M4 – 2
DIN2
Yellow On
Digital input 2 = high
Off Digital input 2 = low
Red On
Overload
M5 – 1
DIN3
Yellow On
Digital input 3 = high
Off
Digital input 3 = low
Red On
Overload
M5 – 2
DIN4 Yellow On Digital input 4 = high
Off
Digital input 4 = low
Red On
Overload
3.2 Diagnostic LED
LED
No.
Colour
Description
Signal status
Meaning
1
Dual
Red/green
Device status
Off
Device is not ready for operation,
No mains or control voltage
Green On
Device is enabled (inverter is working)
Flashing
green
0.5 Hz
Device is ready to switch-on, but not
enabled
4 Hz
Device is in switch-on inhibit
Red/green
4 Hz
Warning
Changing
1…25 Hz
Overload level of the switched on device
Flashing
red
Error,
Flashing frequency = error code (group)
(e. g.: 3 x flashing = E003)