2 Assembly and installation
BU 0800 en-4521 35
The assignment of the correct brake or brake coil voltage must be taken into consideration in the
design with regard to the device’s mains voltage.
Parameter P107/P114
When connecting an electromechanical brake to the respective terminals of the device, you need to
adjust the parameters P107 and P114 (“Brake reaction time” and “Brake delay off”). Set value ≠ 0 in
parameter P107 to avoid damages in the brake control.