EasyManua.ls Logo

Nord Drivesystems SK 300P Series - Page 97

Nord Drivesystems SK 300P Series
160 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5 Parameter
BU 0800 en-4521 97
P516 Skip frequency 1 S P
Setting range
0.0 … 400.0 Hz
Factory setting
{ 0.0 }
Description
The output frequency around the frequency in the range between +P517 and -P517
set here is not displayed.
This range is transmitted with the set deceleration and acceleration ramp; it cannot be
continuously supplied to the output.
Note
Frequencies below the absolute minimum frequency should not be set.
Setting values
0.0
Skip frequency inactive
P517 Skip freq. area 1 S P
Setting range
0.0 … 50.0 Hz
Factory setting
{ 2.0 }
Description
Skip range for "Skip freq. area 1" P516. This frequency value is added and subtracted
from the skip frequency.
Skip range 1: (P516 - P517) ... (P516) … (P516 + P517)
P518 Skip frequency 2 S P
Setting range
0.0 … 400.0 Hz
Factory setting
{ 0.0 }
Description
The output frequency around the set frequency in the range between
+P519
and -P519 set here is not displayed.
This range is transmitted with the set deceleration and acceleration ramp; it cannot be
continuously supplied to the output.
Note
Frequencies below the absolute minimum frequency should not be set.
Setting values
0.0
Skip frequency inactive
P519 Skip range 2 S P
Setting range
0.0 … 50.0 Hz
Factory setting
{ 2.0 }
Description
Skip range for "Skip frequency 2" P518. This frequency value is added to and
subtracted from the skip frequency.
Skip range 2: (P518 - P519) … (P518) ... (P518 + P519)

Table of Contents

Related product manuals