Troubleshooting
6-7
Part 1107600_03
 2014 Nordson Corporation
Table 6‐3 Motor Drive Faults (contd)
Code Name Possible Cause Corrective Action
OHF [DRIVE OVERHEAT] Drive temperature too high Check the motor load, the drive
ventilation, and the environment. Wait for
the drive to cool before restarting.
OLF [MOTOR
OVERLOAD]
Excessive motor current Check the motor load. Wait for the drive
to cool before restarting
OPF [MOTOR PHASE
LOSS]
Loss of one phase at drive output
Output contactor open
Motor not connected or motor
power too low
Instantaneous instability in the
motor current
Check the connections from the drive to
the motor.
OSF [MAINS
OVERVOLTAGE]
Line voltage too high or line supply
disturbed
Check the line voltage.
USF [UNDERVOLTAGE]
Insufficient line supply or low
voltage condition
Check the supply voltage to the motor
drive.
Motor drive failed Replace the motor drive.