Operating Parameters
B-26
Part 1107600_03
2014 Nordson Corporation
Automatic Fill Timer
78
Automatic Fill Timer
Description:
A count-down timer that can be associated with a switch connected to an
input.
Value:
0 to 90 seconds
Resolution:
1
Default Value:
0 (Disabled)
Format:
Use:
Used in conjunction with input control option 13 or 14. Enable output
control option 6, Alert, to send a signal when the timer expires.
PID Selection
80-87
PID Selection for Hose/Gun Receptacles 1, 2, 3,
and 4
Description:
Used to change the preset PID selections. Use parameter 80 to select
the value for hose 1, parameter 81 to select the value for gun 1, and so
on, up to hose 4/gun 4.
Value:
0 = Hose
1 = Standard gun
2 = Large gun
3 = Air heater
Resolution:
Default Value:
0 or 1 depending on the channel type (hose or gun)
Format:
Use:
Consult your Nordson representative before changing PID settings.
88 - 91
PID Selection for Hose/Gun Receptacles 5, 6, 7,
and 8 (DuraBlue D25, D50, and D100 melters only)
Description:
Used to change the preset PID selections. Use parameter 88 to select
the value for hose 5, parameter 89 to select the value for gun 5, and so
on, up to hose 8/gun 8.
Value:
0 = Hose
1 = Standard gun
2 = Large gun
3 = Air heater
Resolution:
Default Value:
0 or 1 depending on the channel type (hose or gun)
Format:
Use:
Consult your Nordson representative before changing PID settings.