Technical Data
8-2
Part 1107600_03
2014 Nordson Corporation
Heater Specifications
NOTE: Refer to the hose and gun manuals for hose/gun heater
specifications.
Location
Wattage
(see Note A)
Voltage
Cold Resistance
(see Note B)
Pump (single‐stream) or
manifold (dual‐stream)
550 240 V 94.0-110.0 ohms
Tank 2 x 425 240 V 123.0-143.0 ohms each
NOTE A: Nominal wattage at 177-204 C (350-400 F).
B: Measured at room temperature for a previously heated element.
Motor and Pump Specifications
Item Data Note
Viscosity range
Melter with filter Up to 35 kg/hr: 500–30,000 cps
Maximum hydraulic pressure
Melter with filter Up to 35 kg/hr: 75 bar (1100 psi)
Displacement
Single-stream:
7.73 cc/rev (35 kg/hr)
A
Pump speed Up to 35 kg: 80 rpm
NOTE A: Displacement per hour shown at 80 rpm motor speed.