Operating Parameters
The melter uses operating parameters to store noneditable and editable
values. Noneditable values are those that provide information about the
historical performance of the melter. Editable values are either a numeric
setpoint or a control option setting. Control option settings affect the display
of information or the function of the melter.
Operating parameters are stored in the melter's firmware in the form of a
sequentially numbered list. The list is organized into the logical groups
described in Table 3‐4.
Table 3‐4 Parameter Groups
Group
Parameter
Numbers
Group Description
Standard
0 to 8 and
10 to 14
Frequently used parameters
Pressure Control 15 to 17 Configure pressure settings
Temperature Control 20 to 29 Control heater function
Input Setup 34 to 39 Configure the optional inputs
Output Setup 43 to 46 Configure the optional outputs
Seven-day Clock 50 to 77 Configure the clock feature
Automatic Fill Timer 78 Configure the external motor control switch
PID Selection 80 to 91 Configure the PID settings
In addition to the ability to read and edit parameter values, you can also save
and restore the current value of every operating parameter and review a log
of the last ten changes that were made to editable parameters.