Output Setup
43 Optional Output 4
Description:
Control options that determine the function of one of the optional outputs
provided when either the optional I/O expansion card (digital) or the I/O
analog board is installed on the CPU board.
Value:
1 = Ready
2 = Ready and motor is on
3 = Fault
4 = Low level
5 = Service LED is on
6 = Alert (Potential fault)
9 = Heaters On
10 = Standby Output
14 = Motor Running
Resolution:
1
Default Value:
0 (all optional outputs)
Format:
Use:
Refer to the instruction sheet provided with the optional I/O expansion
card or analog I/O board for information about wiring and setting up the
optional outputs.
When control option 6, Alert is selected, the output is active whenever the
melter enters the two minute fault monitoring period. If the potential fault
condition clears before the end of the two minute period, the output signal
ends. Refer to Section 4, Operation, Monitor Melter Faults, for
information about fault monitoring.
44 - 46
Optional Outputs 5, 6, and 7
Description:
Control options that determine the function of three of the optional
outputs provided when the optional I/O expansion card (digital) is
installed on the CPU board.
Value:
1 = Ready
2 = Ready and motor is on
3 = Fault
4 = Low level
5 = Service LED is on
6 = Alert (Potential fault)
9 = Heaters On
10 = Standby Output
14 = Motor Running
Resolution:
1
Default Value:
0 (all optional outputs)
Format:
Use:
Refer to the instruction sheet provided with the optional I/O expansion
card for information about wiring and setting up the optional outputs.
When control option 6, Alert is selected, the output is active whenever the
melter enters the two minute fault monitoring period. If the potential fault
condition clears before the end of the two minute period, the output signal
ends. Refer to Section 4, Operation, Monitor Melter Faults, for
information about fault monitoring.