Operating Parameters
B-13
Part 1107600_03
2014 Nordson Corporation
36 - 39
Optional Inputs 7, 8, 9, and 10
Description:
Control options that determine the function of four of the optional inputs
provided when the optional I/O expansion card (digital) is installed on the
CPU board.
Value:
0 – Input Disabled
1 – Standby On/Off
2 – Heaters On/Off
3 – Motor Enable/Disable
4 – Hose/Gun 1 Enable/Disable
5 – Hose/Gun 2 Enable/Disable
6 – Hose/Gun 3 Enable/Disable
7 – Hose/Gun 4 Enable/Disable
8 – Hose/Gun 5 Enable/Disable
9 – Hose/Gun 6 Enable/Disable
11 – Motor 2 Enable/Disable (DuraBlue D50 and D100 melters only)
13 − Automatic Fill Timer 1
14 − Automatic Fill Timer 2 (DuraBlue D50 and D100 melters only)
Resolution:
1
Default Value:
0 (disabled)
Format:
—
Use:
Multiple inputs can be set to the same input value. After one or more
inputs that have the same input value are energized, the input
functionality will not be considered inactive (off) until all of the inputs with
the same input value are de-energized (Multiple inputs set to the same
input value are logical ORed.).
NOTE: Parameter 78, Automatic Fill Timer, must be set to a value of 1 or
greater in order to use option 13 or 14. Output option 6, Alert, can be
used to signal when the Automatic Fill Timer expires.