Setting Up the Motor Control
The motor control parameters are factory set, but may need to be changed
depending on your specific application. Follow this procedure to check and, if
needed, change the motor control parameters. The motor control parameters
are accessed through the motor control panel located on the front of the
melter.
To view or change a motor control parameter
1. Switch the melter OFF.
2. Press and hold both Pump speed arrow keys and then switch the
control switch back on. When the pump speed display indicates SEt,
release the keys.
3. Use the Pump speed arrow keys to select a value for the parameter
shown on the pump speed display. Refer to Table 3‐7 for a parameter list.
4. Press the Pump mode key to save the value and move to the next
parameter.
5. Repeat steps 3-4 for each parameter you want to change.
6. To exit the setup mode, press the Pump mode key one additional time
after the last parameter has been displayed.