Installation
3-31
Part 1107600_03
2014 Nordson Corporation
Table 3‐7 Motor Control Parameter Factory Settings
Parameter Description Factory Setting Explanation
SEt Maximum pump rpm 100
NOTE: This
setting must be
changed for all
AltaBlue TT
melters. Refer
to Explanation.
This parameter controls the increment of
change in motor speed that occurs upon
each press of the pump speed up or
down arrow key when the melter is
operating in the manual mode. To
change the rpm in increments of 1
(recommended for most applications),
enter the maximum pump rpm. The
settings for an AltaBlue TT melter are as
follows:
All melters except 50 kg/hr
melters: 80
50 kg/hr melters only: 115
NOTE: Refer to Melter Assembly Part
Number in Section 7, Parts, to determine
the configuration of your melter.
Srt Motor start mode 1 This parameter controls the method used
to start the motor.
For AltaBlue TT melters, ensure that this
setting is 1. A setting of 1 allows the
motor to start when the pump enable
signal is activated.
LoS Minimum pump speed
in gear‐to‐line mode
0 If the melter will be operated in the
manual mode, enter 0.
If the melter will operated in the
gear‐to‐line mode, enter a minimum line
speed. The motor speed will not fall
below this valve even if the signal drops
to 0 V.