Troubleshooting
6-14
Part 1107600_03
2014 Nordson Corporation
Motor Drive Parameter Settings (contd)
Table 6-9 Motor Drive FUn Menu Parameter Settings
(contd)
Settings
Menu
Parameter
Factory
Setting
Customer
Setting
Settings
Menu
Parameter
Factory
Setting
Customer
Setting
FUn- PSS FUn-
PS2 LI3 CHP
PS4 LI4 CHP nO
PS8 nO UnS2
PS16 nO FrS2 50Hz
SP2 10Hz nCr2
SP3 15Hz nSP2
SP4 20Hz COS2
SP5 25Hz UFt2 n
SP6 30Hz UFr2 20%
SP7 35Hz FLG2 20%
SP8 40Hz StA2 20%
SP9 45Hz SLP2 100%
SP10 50Hz Lst
SP11 55Hz LAF nO
SP12 60Hz Lar nO
SP13 70Hz LAS nSt
SP14 80Hz ArE nO
SP15 90Hz SCS nO
SP16 100Hz CFG Std
FCS nO
NOTE: Shaded parameters do not appear in on the display because of values set in corresponding functions.
Table 6-10 Motor Drive FLt Menu Parameter Settings
Settings
Menu
Parameter
Factory
Setting
Customer
Setting
Settings
Menu
Parameter
Factory
Setting
Customer
Setting
FLt FLt- OLL YES
Atr nO SLL FSt
tAr 5 COL FSt
rSF nO tnL YES
FLr nO LFL YES
EtF nO LFF 10Hz
Let HIG drn nO
EPL YES StP nO
OPL YES InH nO
IPL YES rPr nO
OHL YES rP nO
NOTE: Shaded parameters do not appear in on the display because of values set in corresponding functions.