Operating Parameters
B-4
Part 1107600_03
2014 Nordson Corporation
Standard (contd)
6
Service LED Heater Hours (Noneditable)
Description:
A timer indicates how many more hours the heaters need to remain on
before the service LED illuminates (service required).
Value:
0 hours (disabled) to 9999
Resolution:
1 hour
Default Value:
0
Format:
Use:
The service interval time (parameter 5) must be enabled before this
parameter will work.
Note: Heater hours accumulate whenever the heaters LED is illuminated.
7
Motor Off Delay
Description:
Determines the amount of time the motor will remain on after the
switching device turns off.
Value:
0 to 360 seconds
OR
- - - - (infinite)
Resolution:
seconds
Default Value:
0 seconds
Format:
Use:
This parameter functions only when a switching device (switched
handgun hose, footswitch, etc.) is connected to the switch receptacle.
8
Automatic Pump On
Description:
Determines if the pump can be enabled before the melter is ready so that
the pump will turn on automatically when the melter is ready.
Value:
0 = disabled or 1 = enabled
Resolution:
Default Value:
1 (enabled)
Format:
Use:
If Automatic Pump On is disabled, you must press the pump key to turn
the pump on when the melter is ready.
If Automatic Pump On is enabled and the pump is enabled, the pump will
turn on automatically when the melter is ready.
NOTE: If Automatic Pump On is disabled (0) while the pump is running,
the pump will remain on until the pump key is pressed.