Installation
3-5
Part 1107600_03
î 2014 Nordson Corporation
Table 3â1 Minimum Installation Clearances
Item Description
Required
Clearance
A4
A
Width of melter at the outside of the mounting brackets.
363 mm
(14.29 in.)
B
Clearance required between the melter and the nearest
object in order to remove the filter.
203 mm
(8.00 in.)
C
Clearance required for electrical enclosure ventilation.
100 mm
(4.00 in.)
D
Clearance required between the front end of the melter
(control panel) and the nearest object in order to fully
open the electrical enclosure door
281 mm
(11.05 in.)
E
Minimum horizontal space required for the melter when
both the electrical enclosure door and tank lid are fully
opened.
900 mm
(35.42 in.)
F
Minimum vertical space required for the melter when
the tank lid is at its highest point.
640 mm
(25.18 in.)