Operation
4-11
Part 1107600_03
2014 Nordson Corporation
Heated components with a
setpoint temperature of zero degrees are
skipped during the automatic scan cycle.
The setpoint temperature of the tank and
the pump cannot be set independently.
The time remaining on the ready delay
appears in the right display at the end of each
scan cycle.
Appendix B, parameter 4
You can override the seven-day clock at
any time. If the clock has turned the heaters
off, pressing the heaters key will turn
the heaters back on. If the clock has placed
the melter into the standby mode, pressing
the standby key will return the
heated components to their assigned setpoint
temperature.
Section 4, Using Melter Function
Keys