DJ-2000 Troubleshooting
A. Nozzle Is Capping Over (tip is covered with fluid)
Possible Cause Recovery
 Heat setting is too low
 Raise the temperature. Refer to Section 4 – Heater
Control for Windows (HCW) of the Fluidmove for
Windows Installation and User Guide.
 Incorrect Micrometer or
Preload settings
 Adjust the Micrometer and/or Preload screw.
 Inadequate purge routine
 Increase purge time. Refer to DJ-2000 Operations
Manual.
 Fluid continuously oozing
from the nozzle
 Incorrect offset of the air piston to jet body. Refer to
“Adjusting the Air Piston” DJ-2000 Operations
Manual.
B. Tear Shaped Dots Or Poor Dot Quality
Possible Cause Recovery
 Heat setting is too low
 Raise the temperature. Refer to Section 4 – Heater
Control for Windows (HCW) of the Fluidmove for
Windows Installation and User Guide.
 Incorrect Micrometer or
Preload settings; Preload
screw may not be tight
enough
 Adjust the Micrometer and/or Preload screw.
C. Dots Are Not Round
Possible Cause Recovery
 Dirty nozzle
 Clean the nozzle with solvent and cleaning wire
(provided in DJ-2000 Spare Parts Kit). Refer to
nozzle cleaning procedure in Valve Operations
Manual.
 Damaged nozzle  Replace the nozzle.
 Incorrect temperature
 Set the correct temperature. Refer to Section 4 –
Heater Control for Windows (HCW) of the Fluidmove
for Windows Installation and User Guide.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson Asymtek X-1010 and is the answer not in the manual?

Nordson Asymtek X-1010 Specifications

General IconGeneral
BrandNordson
ModelAsymtek X-1010
CategoryDispenser
LanguageEnglish

Related product manuals