Installation
3-21
Part 1089210A04
E 2010 Nordson Corporation
Configuration 2Configuration 1FunctionDisplay
PCTL Power control algorithm Y = Enable Power Control
mode
N = Use current control
mode (default)
If set to PCTL Y, the power control algorithm controls the total power output to reduce
the variation of power over the life of the magnetron.
PCTL N is the default and preferred method of control (current control).
LAN Language in which faults
are displayed
ENG=English FR=French
IT=Italian
GE=German
SP=Spanish
Use this setting to choose the language faults will be displayed. English is the default
language.
IDLE Enabling IDLE mode
allows return to Lamp ON
mode within 3 seconds
(utilize the Standby
command for activation).
This is done by operating
the lamp system at a low
power, which is not
capable of curing with
minimal heat on substrate.
IDLE N=No
Not enabled
IDLE Y=Yes
Operation of IDLE mode
(local or remote) through
Standby control. See
Installation Section for
proper sequence.
VSPD Lampheads with an
internal blower may
incorporate variable speed
control to provide
consistent bulb
temperature.
VSPD N=No
Set to N if lamphead is not
equipped with internal
blower
VSPD Y=Yes
Enables speed control
Note: Set only if internal
blower lamphead in
utilized.
PWROFF POWER OFF No selection No selection
This is a message instructing you to turn the power supply switch OFF to save your
settings in flash memory.