Troubleshooting
6-13
Part 1126931_01
2018 Nordson Corporation
Error Code
(Hex)
Error Code
(Dec)
Fault Type
Keypad Description
0x8111 33041 Configurable TO RxPDO1 CAN time-out Rx PDO 1
0x8112 33042 Configurable TO RxPDO2 CAN time-out Rx PDO 2
0x8113 33043 Configurable TO RxPDO3 CAN time-out Rx PDO 3
0x8131 33073 Configurable CAN hbeat C1 CAN heartbeat time-out consumer 1
0x8132 33074 Configurable CAN hbeat C2 CAN heartbeat time-out consumer 2
0x8133 33075 Configurable CAN hbeat C3 CAN heartbeat time-out consumer 3
0x8134 33076 Configurable CAN hbeat C4 CAN heartbeat time-out consumer 4
0x8141 33089 Configurable WD exprd Fieldbus watchdog expired
0x8142 33090 Configurable Cycl data left Fieldbus disruption of cyclic data exchange
0x8143 33091 Configurable Inval cycl data Fieldbus invalid cyclic process data
0x8190 33168 Configurable TO Modbus Modbus network time-out
0x8191 33169 Warning Modbus EC Modbus wrong request from master
0x8192 33170 Fault FLBS new module Fieldbus new module detected fault
0x8193 33171 Fault FLBS confg error Fieldbus module configuration mismatch fault
0x8286 33414 Configurable F.PDO mapping Fieldbus PDO mapping error
0xFF06 65286 Configurable OS motor Motor over speed
0xFF09 65289 Configurable F.VolPhases Motor phase failure
0xFF0A 65290 Configurable F.VolPhaseU Motor phase failure phase U
0xFF0B 65291 Configurable F.VolPhaseV Motor phase failure phase V
0xFF0C 65292 Configurable F.VolPhaseW Motor phase failure phase W
0xFF0D 65293 Configurable OC motor Motor over current
0xFF10 65296 Configurable F.AIn01 Analog input 1 fault
0xFF13 65299 Configurable F.AIn02 Analog input 2 fault
0xFF15 65301 Warning W.UV dc link DC link circuit under-voltage warning
0xFF16 65302 Warning F.AOut01 Analog output 1 fault
0xFF18 65304 Warning W.OV dc link DC link circuit over-voltage warning
0xFF19 65305 Warning F.AOut02 Analog output 2 fault
0xFF40 65344 No response TMO no reaction Test monitor generated no reaction
0xFF41 65345 Warning TMO warning Test monitor generated warning
0xFF42 65346 Trouble TMO trouble Test monitor generated trouble
0xFF43 65347 Fault TMO fault Test monitor generated fault
0xFF44 65348 Fault TMO fault delay Test monitor generated fault with fault reset delayed
0xFF45 65349 Fault TMO fault block Test monitor generated fault with fault reset blocked
0xFF48 65352 Fault Safety fault Safety supervision fault
0xFF49 65353 Fault EPM invalid data EPM contains invalid user data
0xFF50 65360 Fault EPM not present EPM not present
Continued...