Installation
3-27
Part 1126931_01
2018 Nordson Corporation
Set Up Inputs/Outputs
Set up the parameter control option for each input and output that you
connected to the melter. Table 3‐6 lists the available control options. Refer to
Setting Up the Melter earlier in this section for information about how to
select operating parameters and edit parameter control options.
With the exception of the motor
enable/disable control option (Table 3‐6,
Input/Output Data), All inputs are
transition‐based.
Input Setup in Appendix B
The input capacity of the melter may be
increased from four inputs to a total of
ten inputs by adding an optional I/O
expansion card that is available from
Nordson Corporation.
Section 7, Parts
The output capacity of the melter may
be increased from three outputs to
seven outputs by adding an optional I/O
expansion card that is available from
Nordson Corporation.
Section 7, Parts
Table 3‐6 Input/Output Data
Item Description
Operating
Parameter
Control Options Terminals Notes
1 Standard input 1 30 0 - Input Disabled
1 - Standby On/Off
2 - Heaters On/Off
3 - Motor 1 Enable/Disable
4 - Hose/Applicator 1
Enable/Disable
5 - Hose/Applicator 2
Enable/Disable
6 - Hose/Applicator 3
Enable/Disable
7 - Hose/Applicator 4
Enable/Disable
8 - Hose/Applicator 5
Enable/Disable
9 - Hose/Applicator 6
Enable/Disable
10 – Automatic standby (Default)
11 - Motor 2 Enable/Disable
XI:1, XI:2 A, B
C
D
C
Continued...