Standby key
Operation
4-25
Part 1126931_01
2018 Nordson Corporation
Standby Key
Use the standby key to manually place the melter into, and take it out of, the
standby mode. Using the standby mode during periods of time when the
melter is inactive helps conserve energy and allows heated components to
quickly return to their set‐point temperatures when the melter is once again
needed.
When the melter is placed into the standby mode, the temperatures of all
components are reduced down from their set‐point temperature by a pre‐set
standby delta. The melter will remain in the standby mode until the standby
key is pressed or the function of one of the operating parameters takes the
melter out of the standby mode.
If the melter was set up to use the manual standby timer (Parameter 26),
pressing the standby key will place the melter in the standby mode for the
period of time specified by the timer. After the manual standby time has
elapsed, the melter will once again begin heating all of the components to
their assigned set‐point temperature.
Using the standby key overrides the control of the melter (on or off) by the
seven‐day clock or a remote input.
Refer to Section 3, Installation, Setting Up the Melter, and to Appendix B,
Operating Parameters, for information about setting the standby delta and
the standby timer.
The melter may also be set up to automatically
enter the standby mode using a variety of
operating parameters.
Appendix B, Parameters 25, 26, 57,
30–33, 62, and 67
Whenever manual standby is enabled, the standby
LED blinks.
Appendix B, Parameter 26