Installation
3-31
Part 1126931_01
2018 Nordson Corporation
Setting Up Gear‐to‐Line Operation
If you want to use the gear‐to‐line capability, install a (customer‐supplied)
line‐speed signal generator to measure the speed of the production line. The
AltaBlue motor control accepts a 0-10 VDC analog input signal.
NOTE: Nordson offers a 0-10 VDC line‐speed signal generator. Refer to
Optional Accessories in Section7, Parts, for the part number.
To use the gear‐to‐line capability, connect a 0-10 VDC signal from a
customer‐supplied line‐speed signal generator to the appropriate terminals
on terminal block XI inside the electrical enclosure. See Figure 3‐6 for the
location of terminal block XI. Refer to Table 3‐6 for the terminal numbers that
correspond to each input/output.