Troubleshooting
6-15
Part 1126931_01
2018 Nordson Corporation
Changing a Motor Drive Parameter
Keypad
The motor drive parameters are pre‐set at the factory. You need the motor
drive keypad with display to view and change the motor drive parameters.
Install the keypad on the front of the motor drive.
An explanation of the keypad button functions is given in the following table.
Keypad Buttons Description
Anal og I nput 1
PAR 43 0
LOC REM MAN AUTO
SET8
Menu navigation
Adjust parameter values
Enter (sub-) menu/parameter
Confirm parameter
Exit (sub-) menu/parameter
Stop motor drive
Release motor drive
Display
An explanation of the display parameters is given in the following table.
Display Item Description
Vel:Run:FWD Hz
LOC
20. 0
REM MAN AUTO SET
1
2
3
1 Status and unit
2 Speed, Parameter value, and Fault code
3
LOC – Local start button on keypad is active
(stop button is always active)
REM – Local start button is inactive (start is
initiated remotely)
MAN – Up/Down arrows are active and control
speed
AUTO – Up/Down arrows are inactive (speed
control is external)
SET8 – The blinking indicates that a setting or
value has changed and needs to be entered.
Once the settings are saved, the icon is steady