Operating Parameters
B-12
Part 1126931_01
2018 Nordson Corporation
Output Setup
40 - 42
Outputs 1, 2, and 3
Description:
Determines the function of the output.
Value:
0 = Output Disabled
1 = Ready
2 = Ready and Pump is on
3 = Fault
4 = Low level
5 = Service LED is on
6 = Alert
Resolution:
1
Default Value:
Output 1 = 1
Output 2 = 3
Output 3 = 4
Format:
—
Use:
Refer to Installing Melter Outputs in Section 3, Installation, for information on
setting up outputs.
When control option 6, Alert is selected, the output is active whenever the melter
enters the two minute fault monitoring period. If the potential fault condition
clears before the end of the two minute period, the output signal ends. Refer to
Section 4, Operation, Monitor Melter Faults, for information about fault
monitoring.
43 - 46
Optional Outputs 4, 5, 6, and 7
Description:
Control options that determine the function of the four optional outputs provided
when the optional I/O expansion card is installed on the main board.
Value:
0 = Output Disabled
1 = Ready
2 = Ready and Pump is on
3 = Fault
4 = Low level
5 = Service LED is on
6 = Alert (Potential fault)
Resolution:
1
Default Value:
1 (all optional outputs)
Format:
—
Use:
Refer to the instruction sheet provided with the optional I/O expansion card for
information about wiring and setting up the optional outputs.
When control option 6, Alert is selected, the output is active whenever the melter
enters the two minute fault monitoring period. If the potential fault condition
clears before the end of the two minute period, the output signal ends. Refer to
Section 4, Operation, Monitor Melter Faults, for information about fault
monitoring.