Operating Parameters
B-11
Part 1126931_01
2018 Nordson Corporation
33
Input 4
Description:
Control options that determine the function of input 4.
Value:
0 - Input Disabled
1 – Standby On/Off
2 – Motor 1 On/Off
3 – Motor Enable/Disable
4 – Hose/Applicator 1 Enable/Disable
5 – Hose/Applicator 2 Enable/Disable
6 – Hose/Applicator 3 Enable/Disable
7 – Hose/Applicator 4 Enable/Disable
8 – Hose/Applicator 5 Enable/Disable
9 – Hose/Applicator 6 Enable/Disable
11 - Motor 2 Enable/Disable
Resolution:
1
Default Value:
4
Format:
Use:
If Motor Enable/Disable (3) is selected, the motor will not turn on unless the
pump is enabled and the correct voltage is present on the input contacts.
Refer to Installing Melter Inputs in Section 3, Installation, for information about
setting up inputs.
NOTE: Multiple inputs can be set to the same input value. After one or more
inputs that have the same input value are energized, the input functionality will
not be considered inactive (off) until all of the inputs with the same input value
are de‐energized (Multiple inputs set to the same input value are logical ORed.).
34 – 39
Optional Inputs 5, 6, 7, 8, 9, and 10
Description:
Control options that determine the function of the six optional inputs provided
when the optional I/O expansion card is installed on the main board.
Value:
0 - Input Disabled
1 – Standby On/Off
2 – Motor 1 On/Off
3 – Motor Enable/Disable
4 – Hose/Applicator 1 Enable/Disable
5 – Hose/Applicator 2 Enable/Disable
6 – Hose/Applicator 3 Enable/Disable
7 – Hose/Applicator 4 Enable/Disable
8 – Hose/Applicator 5 Enable/Disable
9 – Hose/Applicator 6 Enable/Disable
11 - Motor 2 Enable/Disable
Resolution:
1
Default Value:
0 (Disable)
Format:
Use:
If Motor Enable/Disable (3) is selected, the motor will not turn on unless the
pump is enabled and the correct voltage is present on the input contacts.
Refer to Installing Melter Inputs in Section 3, Installation, for information about
setting up inputs.
NOTE: When more than one input is set to the same value, the controller follows
the state of the active input.