Set‐point Temperature of the Tank, Hoses, and Applicators
The melter is shipped from the factory with the tank set‐point temperature at
175 C (350 F) and the hose and applicator set‐point temperatures at 0
degrees (turned off).
Before the melter can be used, a set‐point temperature must be assigned to
the tank, hoses, and applicators. Assign set‐point temperatures using any of
the following methods:
Global—The tank and all hoses and applicators are set to the same
set‐point temperature.
Global‐by‐component group—All of the hoses or all of the applicators
are set to the same set‐point temperature.
Individual Component—The set‐point temperature of the tank and each
hose and applicator is set individually.
Since most manufacturing processes will require the tank, hoses, and
applicators to be set to the same temperature, only the global method of
assigning set‐point temperatures is described in this section. For information
about the other two methods of assigning set‐point temperatures, refer to
Adjusting Component Temperatures in Section 4, Operation.
As with operating parameters, you can also save and restore set‐point
temperatures and review past changes that were made to set‐point
temperatures.