Installation
3-19
Part 1126931_01
2018 Nordson Corporation
Parameter Name Range of Values Default Value
71 Schedule for Monday 0-7 0
72 Schedule for Tuesday 0-7 0
73 Schedule for Wednesday 0-7 0
74 Schedule for Thursday 0-7 0
75 Schedule for Friday 0-7 0
76 Schedule for Saturday 0-7 0
77 Schedule for Sunday 0-7 0
You can exit the setup mode at any time by
pressing the Setup key.
Parameter numbers that are not applicable are
skipped when you scroll through the operating
parameter list in the left display.
When the right display is flashing, you can
quickly set the value of the current parameter
to its lowest possible value by simultaneously
pressing both of the right‐display scroll keys.
While in the setup mode, if no key is pressed
for two minutes, the melter will return to the
automatic scan mode.
You can also use the right‐display scroll keys
to enter or change a parameter's value or
control option. After entering the parameter's
number in the left display, press either of the
right‐display scroll keys to change the value or
control option.
Using a personal computer that is connected
to the melter through the serial port, you can
view and change all of the operating
parameters from a single computer screen.
Refer to Appendix C, Melter
Communications
If password protection is enabled, the melter
will return to the password protected mode
whenever you exit the setup mode.
Appendix B, Parameter 10