Technical Data
8-2
Part 1126931_01
2018 Nordson Corporation
Electrical Data
WARNING! The unit is designed for only one operating voltage. Operate
only at the operating voltage shown on the ID plate.
Available operating
voltages
400 V
AC
3‐phase with neutral (star — WYE)
Maximum melter power
requirements
20L 14740 W
45L 16540 W
Operating voltage
frequency
50/60 Hz
Fuse protection Refer to ID plate
Melter Internal Heater
Power Wattage
20L 45L
Grid: 3x900 W Grid: 5x900 W
Manifold: 3x800 W Manifold: 3x800 W
Max. load per hose
receptacle
1000 W, any single hose or applicator
1200 W, any hose/applicator pair
2000 W, sum of hose/applicator pairs 1 and 2
2000 W, sum of hose/applicator pairs 3 and 4
2000 W, any single hose, or applicator 5 or 6
2000 W, hose/applicator pair 5 or 6
4000 W, sum of hose/applicator pairs 5 and 6
NOTE: Total external wattage must not exceed 8,000 W.
Mechanical Data
Item 20L 45L
Weight 205 kg (451 lb) 240 kg (529 lb)
Tank opening (length and
width)
170 x 250 mm 170 x 250 mm
Melter Appearance (length,
width and height)
1250 x 600 x 1230 mm 1250 x 600 x 1230 mm
Approximate tank volume 20 L 45 L
Number of hose connections Single‐stream manifolds: 2 connections per pump stream