Display (contd)
Every parameter has a hexadecimal address. Parameters which are visible
on the keypad also have a display code. In the Easy Starter Display Code
and hexadecimal address are visible. Every parameter can have
sub-parameters.
Example Display code Address
V/f base frequency P302.02 0x2B01:002
Start control P200.00 0x2824:000
The parameters are organized into groups 0 through 7:
Group Name Group Name
0 Favorites menu 4 Function and I/O menu
1 Diagnostics 5 Network setup menu
2 Basic setup 6 Process control menu
3 Motor setup 7 Auxiliary function menu
The favorites menu contains links to the most commonly used parameters for
initial commissioning and monitoring of the motor drive for general
applications.