Installation
3-30
Part 1126931_01
2018 Nordson Corporation
Set Up Inputs/Outputs (contd)
Table 3‐6 Input/Output Data
(contd)
Item Description
Operating
Parameter
Control Options Terminals Notes
13 Motor 3
remote start
(See Note J)
XI:29, XI:30 Connect a
momentary,
normally open
contact to the
terminals.
14 Motor 3
remote stop
(See Note J)
XI:31, XI:32 Connect a
momentary,
normally open
contact to the
terminals.
15 Motor 4
remote start
(See Note J)
XI:33, XI:34 Connect a
momentary,
normally open
contact to the
terminals.
16 Motor 4
remote stop
(See Note J)
XI:35, XI:36 Connect a
momentary,
normally open
contact to the
terminals.
17 Motor drive 1
running (optional)
XI:25, XI:26 Refer to Setting
Up Motor Run
Status Monitoring.
18 Motor drive 2
running (optional)
XI:27, XI:28
19 Motor drive 3
running (optional)
(See Note J)
XI:37, XI:38 Refer to Setting
Up Motor Run
Status Monitoring.
20 Motor drive 4
running (optional)
(See Note J)
XI:39, XI:40
J: Motors 3 and 4 are present only on three/four pump or 100L melters.