Installation
3-29
Part 1126931_01
2018 Nordson Corporation
Table 3‐6 Input/Output Data (contd)
Item Description
Operating
Parameter
Control Options Terminals Notes
6 Standard output 2 41 Same as parameter 40
(Default=3)
XI:11, XI:12
7 Standard output 3 42 Same as parameter 40
(Default=4)
XI:13, XI:14
8 Key‐to‐line
0-10V input
XI:15 (+),
XI:16 (-)
Refer to Setting
Up Gear‐to‐Line
Operation
9 Motor 1
remote start
XI:17, XI:18 Connect a
momentary,
normally open
contact to the
terminals.
10 Motor 1
remote stop
XI:19, XI:20 Connect a
momentary,
normally open
contact to the
terminals.
11 Motor 2
remote start
XI:21, XI:22 Connect a
momentary,
normally open
contact to the
terminals.
12 Motor 2
remote stop
XI:23, XI:24 Connect a
momentary,
normally open
contact to the
terminals.