Installation
3-17
Part 1126931_01
2018 Nordson Corporation
If the numeric set‐point or control option is not accepted, the right
display will indicate dashes (‐‐‐‐) for three seconds and then it will
change back to the original value.
8. Repeat step 5 through step 7 to read or change the next sequential
parameter number or press the Setup key to exit the setup mode.
Table 3‐4 Operating Parameters
Parameter Name Range of Values Default Value
Standard
0 Enter Password 0 to 9999 4000
1 Total Hours with Heaters On
(noneditable)
0 to 9999 0
2 Fault Log (noneditable) _‐F0 (empty)
3 Change History Log (noneditable) P‐_ (empty)
4 Ready Delay Time 0 to 60 minutes 0 minutes
5 Service Interval Time 0 to 8736 hours 500 hours
6 Service LED Heater Hours 0 to 9999hours 0
8
1
Automatic Pump On 0 (disabled) or 1(enabled) 1 (enabled)
10 Enable or Disable Password 0 (disabled) or 1(enabled) 0 (disabled)
11 Create Password 0 to 9999 5000
12
1
Change Hose 1 Output to Electric
Applicator Activation
0 (disabled) or 1 (enabled) 0 (disabled)
13
1
Change Hose 2 Output to Electric
Applicator Activation
0 (disabled) or 1 (enabled) 0 (disabled)
14 External Communications Lock‐out 0 or 1 0 (disabled)
Temperature Control
20 Temperature Units (degrees C or F) C (degrees Celsius) or F
(degrees Fahrenheit)
C (degrees Celsius)
21 Over Temperature Delta 5 C (10 F) to 60C(110 F) 15 C (25 F)
22 Under Temperature Delta 5 C (10 F) to 60C(110 F) 25 C (50 F)
23 Standby Delta 25 C (50 F) to 190C (350 F) 50 C (100 F)
24 Automatic Standby Timeout 0 to 1440minutes 0 (disabled)
25 Automatic Heaters Off Time 0 to 1440minutes 0 (disabled)
26 Manual Standby Time 0 to 180 minutes 0 (disabled)
27 Hose Standby Delta 1 C (1 F) to 190C (350 F) 0 (disabled)
28 Applicator Standby Delta 1 C (1 F) to 190C (350 F) 0 (disabled)
29 Internal Zone Temperate Offset 0 C (0 F) to ‐15C (‐30 F) 0 (disabled)
30 Standard Input 1
0–8 and 10-14
10 (Automatic
Standby)
31 Standard Input 2 0–8 and 10-14 1 (Standby on/off)
32 Standard Input 3 0–8 and 10-14 2 (Heaters on/off)
33 Standard Input 4
0–8 and 10-14
4 (Hose/applicator 1
enable/disable)
34 Optional Input 5 0–8 and 10-14 0 (disabled)
1
Not used with DuraBlue II melters.