Installation
3-24
Part 1126931_01
2018 Nordson Corporation
Review Parameter and Set‐point Temperature Changes (contd)
Table 3‐5 Change History Log
First Digit
Second
Digit
Third and Fourth Digits
P (Parameter)
-
Indicates the number of the parameter that was changed
S (Set‐point)
Are used in conjunction with the LEDs on the component keys to indicate the
location and method of a set‐point temperature change.
When this LED is
on..
And the Fourth
Digit Indicates..
The change was
to..
And the Method
of Change was..
Tank Key 1 The tank Individual
Hose Key 1– 6 A single hose Individual
Applicator Key 1– 6
A single
applicator
Individual
All Keys 0 All components Global
Hose Key 0 All hoses
Global‐by‐
component
Applicator Key 0 All applicators
Global‐by‐
component
Change History Log Examples
Example 1:
Parameter 4 (ready delay) was changed.
Example 2:
If the LED on the applicator key is on, then this display would
indicate that the global‐by‐component method was used to change the
temperature of the applicators.