Using the Menus
5-35
Part 1124631_01
E 2015 Nordson Corporation
Item Menu Action
d Use one of the three methods of
scaling the pattern controller:
Scale using
product
length

10
a
c
b
1 Measure with the actual
product length in line where
the trigger detects the
product.
2 Tap to select scale by
product length. See a in the
figure on the left.
3 Tap to use a different trigger
input for length
measurement. See b in the
figure on the left.
4 Enter the measured product
length from step 1. See c in
the figure on the left.
NOTE: The hourglass symbol
appears until a product is
detected on the trigger input. If
no product is detected after 30
seconds, the system will keep
the existing scale factor.
5 R un at least one product past
the trigger.
6Thesystemcalculatesthe
resulting scale.
Scale using
line speed

a
b
50
Make sure the line is running at a
known constant speed.
1 T ap to select scale by line
speed. See a in the figure on
the left.
2 Enter the known line speed.
See b inthefigureontheleft.
NOTE: The system calculates
the resulting scale.
NOTE: This method is disabled
until a valid line speed is
detected on the encoder input.
Scale
manually


NOTE: Manual scaling is
normally used only with an
encoder.
1 Tap to scale manually.
2 Enter the number of pulses
per millimeter (or per inch) of
line travel.