4-34
Okuma America Corporation
MACHINE OPERAMACHINE OPERA
MACHINE OPERAMACHINE OPERA
MACHINE OPERA
TIONTION
TIONTION
TION
Rev. 8-21-01
ERROR This is the Error Light activation switch. If this switch is on, the RED
error light will come on if an alarm state is detected.
AUTO This switch is called the Auto Power Shut Off switch. If
POWER this switch is on, the power will shut off automatically
OFF after the execution of an “End of Program” (M02) command or after
executing an “End of Tape” (M30) command in a main program. This
switch is ineffective when single block mode is on. On some of the new
machines this function is a parameter setting. (Optional Parameter Bit 14
bit 0)
Control On/Off
POWER This is the Power On button. Press this button after
ON turning on the main circuit breaker on the side of the control cabinet to
power up the machine.
POWER This is the Power Off button. Press this button first
OFF before turning off the main circuit breaker when turning off the machine.
If any peripherals are hooked up to the machine, they should be powered
off first.
EMG. This is an extra emergency stop button. If any of the E-stop buttons are
pushed
STOP in, the red indicator lamp on this panel will be on. The green indicator
lamp will come on as soon as the main breaker is turned on. It turns off as
soon as the Power On button is pressed.