4-38
4-2 Function Mode
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
4
Parameter List
Others
P001
Operation
Selection on
Option Error
00: Trip
01: Continue operation
00 no yes −−
P003
Pulse Train Input
Terminal RP
Selection
00: Frequency setting
(including PID)
01: Feedback pulse (enabled
only when motor 1 control
is selected)
02: Do not set.
00 no no
5-82
5-160
Simple position control
P004
Feedback Pulse
Train Input Type
Selection
00: Single-phase pulse train
01: Dual-phase pulse train 1
02: Dual-phase pulse train 2
03: Single-phase pulse train
+ direction
00 no no
5-160
P011
Number of
Encoder Pulses
32. to 1024. 512. no no
Pulse
P012
Simple Position
Control
Selection
00: Simple position control
disabled
02: Simple position control
enabled
00 no no
P015
Creep Speed
Setting
Starting frequency to 10.0
(100.0)
5.00 no yes Hz
P026
Overspeed Error
Detection Level
0.0 to 150.0 115.0 no yes %
P027
Speed Deviation
Error Detection
Level
0.00 to 99.99
100.0 to 120.0
10.00 no yes Hz
Others
P031
Acceleration/
Deceleration
Time Input Type
00: Digital Operator
03: Do not set.
00 no no 5-24
Simple torque control
P033
Torque
Reference Input
Selection
00: Terminal FV
01: Terminal FI
03: Digital Operator
06: Optional board
00 no no
5-156
P034
Torque
Reference
Setting
0. to 200. 0. yes yes %
P036
Torque Bias Mode
00: Disabled
01: Set via the Digital
Operator
05: Optional board
00 no no
5-156
P037
Torque Bias Value
200. to +200. 0. yes yes %
P038
Torque Bias
Polarity Selection
00: As per sign
01: Depends on the RUN
direction
00 no no
Parameter
No.
Function name Monitor or data range
Default
setting
Set data
Data can
be set
during
RUN
Data can be
changed
during RUN
Unit