4-39
4-2 Function Mode
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
4
Parameter List
Simple torque control
P039
Speed Limit
Value in Torque
Control
(Forward)
0.00 to 99.99
100.0 to 120.0
0.00 yes yes Hz
5-156
P040
Speed Limit
Value in Torque
Control
(Reverse)
0.00 to 99.99
100.0 to 120.0
0.00 yes yes Hz
P041
Speed/Torque
Control
Switching Time
0 to 1000 ms
Communications options
P044
Communications
Error Detection
Timer Setting
0.00 to 99.99 (S) 1.00 no no
−−
P045
Operation at
Host
Communications
Error Selection
00: Trip
01: Deceleration stop and
then trip
02: Ignore
03: Free-run stop
04: Deceleration stop
01 no no
P046
Assembly Instance
Number
00 to 20 00 no no
P048
Operation at Idle
Mode Detection
Setting
00: Trip
01: Deceleration stop and
then trip
02: Ignore
03: Free-run stop
04: Deceleration stop
01 no no
P049
Number of Poles
for Rotation
Speed Setting
0/2/4/6/8/10/12/14/16/18/20/
22/24/26/28/30/32/34/36/38
0nono
Pulse train input
P055
Pulse Train
Frequency Scale
1.0 to 32.0 25.0 no yes
kHz
5-82
P056
Pulse Train
Frequency Filter
Time Parameter
0.01 to 2.00 0.10 no yes s
P057
Pulse Train Bias
Amount
100. to +100. 0. no yes %
P058 Pulse Train Limit 0. to 100. 100. no yes %
Parameter
No.
Function name Monitor or data range
Default
setting
Set data
Data can
be set
during
RUN
Data can be
changed
during RUN
Unit