EasyManua.ls Logo

Omron 3G3MX2 - Page 299

Omron 3G3MX2
440 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
5-182
5-14 Other Functions
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
5
Functions
* Shaded cells are the same as those for Normal Mode (heavy load rating).
C028 AM Selection 00: Output frequency
01: Output current
02: Output torque
04: Output voltage
05: Input power
06: Electronic thermal load
rate
07: LAD frequency
10: Cooling fin temperature
11
: Output torque (signed)
13: Do not use this setting.
16: Optional board
07 00: Output frequency
01: Output current
04: Output voltage
05: Input power
06: Electronic thermal load
rate
07: LAD frequency
10: Cooling fin temperature
13: Do not use this setting.
16: Optional board
07
C042 Arrival Frequency
During
Acceleration
0.00 to 400.00 [Hz] 0.00 0.00 to 1,000.00 [Hz]
0.00
C043 Arrival Frequency
During
Deceleration
0.00 to 400.00 [Hz] 0.00 0.00 to 1,000.00 [Hz]
0.00
C045 Arrival Frequency
During
Acceleration 2
0.00 to 400.00 [Hz] 0.00 0.00 to 1,000.00 [Hz]
0.00
C046 Arrival Frequency
During
Deceleration 2
0.00 to 400.00 [Hz] 0.00 0.00 to 1,000.00 [Hz]
0.00
P015 Creep Speed
Setting
Starting Frequency to 10.00
[Hz]
5.00 Starting Frequency to
100.00 [Hz]
5.00
P070 Zero Return Mode
1 Frequency
Starting Frequency to 10.00
[Hz]
5.00 Starting Frequency to
100.00 [Hz]
5.00
Parameter
No.
Function name
Normal Mode with a Heavy Load
Rating (CT)
High-frequency Mode
Setting range
Default
Setting range
Default

Table of Contents