5-182
5-14 Other Functions
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
5
Functions
* Shaded cells are the same as those for Normal Mode (heavy load rating).
C028 AM Selection 00: Output frequency
01: Output current
02: Output torque
04: Output voltage
05: Input power
06: Electronic thermal load
rate
07: LAD frequency
10: Cooling fin temperature
11
: Output torque (signed)
13: Do not use this setting.
16: Optional board
07 00: Output frequency
01: Output current
04: Output voltage
05: Input power
06: Electronic thermal load
rate
07: LAD frequency
10: Cooling fin temperature
13: Do not use this setting.
16: Optional board
07
C042 Arrival Frequency
During
Acceleration
0.00 to 400.00 [Hz] 0.00 0.00 to 1,000.00 [Hz]
0.00
C043 Arrival Frequency
During
Deceleration
0.00 to 400.00 [Hz] 0.00 0.00 to 1,000.00 [Hz]
0.00
C045 Arrival Frequency
During
Acceleration 2
0.00 to 400.00 [Hz] 0.00 0.00 to 1,000.00 [Hz]
0.00
C046 Arrival Frequency
During
Deceleration 2
0.00 to 400.00 [Hz] 0.00 0.00 to 1,000.00 [Hz]
0.00
P015 Creep Speed
Setting
Starting Frequency to 10.00
[Hz]
5.00 Starting Frequency to
100.00 [Hz]
5.00
P070 Zero Return Mode
1 Frequency
Starting Frequency to 10.00
[Hz]
5.00 Starting Frequency to
100.00 [Hz]
5.00
Parameter
No.
Function name
Normal Mode with a Heavy Load
Rating (CT)
High-frequency Mode
Setting range
Default
Setting range
Default