4-22
4-2 Function Mode
SYSDRIVE MX2 Series USER'S MANUAL (3G3MX2-A@@@@)
4
Parameter List
Others
b075
Ambient
Temperature
10. to 50. 40. yes yes °C5-127
b078
Integrated
Power Clear
Cleared with the Enter key
after changing to 01
00 yes yes
5-7
b079
Integrated
Power Display
Scale
1. to 1000. 1. yes yes
b082
Starting
Frequency
0.10 to 9.99 (100.) 0.50 no yes Hz 5-57
b083
Carrier
Frequency
2.0 to 15.0/10.0
(heavy load/light load or high
frequency)
* With derating
10.0/
2.0
(5.0)
no yes
kHz
5-51
b084
Initialization
Selection
00: Initialization disabled
01: Fault monitor clear
02: Initializes data
03: Fault monitor clear + Data
initialization
04: Do not set.
00 no no
5-174
b085
Initialization
Data Selection
00: Do not change. 00 no no
b086
Frequency
Conversion
Coefficient
0.01 to 99.99 1.00 yes yes 5-4
b087
STOP Key
Selection
00: Enabled
01: Disabled
02: Only reset is enabled
00 no yes 5-84
b088
Free-run Stop
Selection
00: 0 Hz restart
01: Frequency matching
restart
02: Frequency pull-in restart
00 no yes 5-103
b089
Automatic
Carrier
Reduction
00: Disabled
01: Enabled/depends on
current
02: Enabled/depends on fin
temperature
01 no no 5-52
b090
Usage Rate of
Regenerative
Braking
0.0 to 100.0 0.0 no yes % 5-141
b091 Stop Selection
00: Deceleration stop
01: Free-run stop
00 no yes 5-24
b092
Cooling Fan
Operation
00: Always
01: Only during operation
(including 5 minutes after
power on/stop)
02: Depends on the fin
temperature
01 no yes
5-127
b093
Cooling Fan
Total Operation
Time Clear
00: Total operation time count
01: Clear total operation time
00 no no
Parameter
No.
Function name Monitor or data range
Default
setting
Set data
Data can
be set
during
RUN
Data can be
changed
during RUN
Unit
Page

Table of Contents