15-5
15 Analog I/O Function
CP1E CPU Unit Software User’s Manual(W480)
15-1 Overview
15
15-1-1 Flow of Operation
Reading A/D Conversion Values
Writing D/A Conversion Values
Handling Unit Errors
When an error occurs in the built-in analog I/O system, analog input data will be set to 0000 and the
analog output will be set to 0 V or 0 mA.
If a CPU error occurs, the analog output will be set to is set to 0 V or 0 mA even if the output range is
1 to 5 V or 4 to 20 mA. For any other fatal errors in the CPU Unit, 1 V or 4 mA will be output if the
output range is 1 to 5 V or 4 to 20 mA.
Writing the Ladder Program
MOV
Analog input device
• Temperature sensor
• Pressure sensor
• Speed sensor
• Flow sensor
• Other device
Analog input 0 conversion value
Analog input 1 conversion value
CIO 90
CIO 91
CP1E NA-type CPU Unit
MOV instruction
Ladder program
Read conversion
value.
CP1E NA-type CPU Unit
Analog output device
• Adjustment equipment
• Servo Controller
• Inverter
• Recorder
• Other device
Analog output 1 SV
CIO 190
MOV
MOV instruction
Write conversion
value (SV).
Ladder program