135
Sensor Terminals Section 4-7
The wires cannot be connected in this condition. Cut the stripped portion of
wire off and then remove the sheath as shown in the following illustration. Do
not strip the core wires.
Inserting Core Wires in the Cable Connector
When connecting the sensor, align the senor wires by color with the terminal
numbers printed on the cover according to the following tables.
DRT1-HD16S
DRT1-ND16S
Note Wire colors in parentheses are the previous JIS colors for photoelectric and
proximity sensors.
Insert the core wires completely to the back of the cover holes.
Assembling the Cable Connectors
1,2,3... 1. Confirm that the core wires and terminal number are aligned properly us-
ing the wire colors. Also be sure that the wires are inserted completely to
the back of the cover. (The Cover is transparent so that the wires can be
easily seen.)
2. As shown in the following diagram, press the covers with the cable wires
inserted into it into the plug connector using your hands to temporarily at-
tach it.
3. As shown in the following diagram, use pliers or a similar tool to press the
cover completely into the plug connector. Press on the center of the cover
Terminal
number
3-wire sensor
(without self-
diagnosis output)
2-wire sensor
(without self-
diagnosis output)
3-wire sensor
(without self-
diagnosis output)
1 Black (white) Brown (white) Black (white)
2 --- --- Orange (orange)
3 Brown (red) --- Brown (red)
4 Blue (black) Blue (black) Blue (black)
Terminal
number
Sensor with teaching function
or with self-diagnosis output
Sensor with bank switching
function
1 Black (white) Black
2Pink (gray) Purple
3 Brown (red) Brown
4 Blue (black) Blue
20 mm min.