6
Overview of DeviceNet Section 1-1
Slave Features
I/O Terminals
Provide general-purpose inputs, outputs, or both inputs and outputs via 2-
tier terminal blocks (M3). Available in 8-point and 16-point models with
transistor inputs or outputs or in a 16-point model with 8 inputs and 8 out-
puts.
Provide general-purpose inputs, outputs, or both inputs and outputs via 3-
tier terminal blocks (M3). Available in 16-point models with transistor
inputs or outputs or in a 16-point model with 8 inputs and 8 outputs.
Provide general-purpose inputs, outputs, or both inputs and outputs via a
MIL connector. Available in 32-point models with transistor inputs or out-
puts or in a 32-point model with 8 inputs and 8 outputs.
Environment-resistive Slaves
Environment-resistant Terminals
Improved I/O Terminals that conform to IP66 for spatter-, water-, and oil-
resistance. Sensors or valves with round water-proof connectors can be
easily connected with no tools.
Available in 8-point or 16-point models with transistor inputs or outputs,
and 16-point models with transistor I/O (8 inputs and outputs).
•DRT1-
@@@@C(-1): IP66
Water-proof Terminals
Improved I/O Terminals that conform to IP67 for water- and oil-resistance.
Sensors or valves with round water-proof connectors can be easily con-
nected with no tools.
Available in 4-point or 8-point models with transistor inputs or outputs.
•DRT1-
@@@@CL(-1): IP67
B7AC Interface Unit
Input Interface Unit that conforms to IP66 for spatter-, water-, and oil-
resistance.
Provides three FA connector ports for the B7A for 10 input points on each
of 3 ports.
Remote Adapters
Used in combination with G70D and other I/O Blocks to handle relay out-
puts, power MOS FET Relay outputs, etc.
Available in 16-point models with transistor inputs or outputs.
CQM1 I/O Link Units
More than one I/O Link Unit can be mounted to a CQM1 PLC.
Link 16 inputs and 16 outputs between the PLC and the Master Unit.
Sensor Terminals
Accept inputs from photoelectric and proximity sensors with connectors.
Available in 16-point input and 8-point input/8-point output models.
Output signals can be used for sensor teaching and external diagnosis.
Analog Input Terminals
Convert analog inputs to binary.
Switchable between 2 and 4 input points using the DIP switch.
Handle inputs of 0 to 5 V, 1 to 5 V, 0 to 10 V, –10 to 10 V, 0 to 20 mA, or 4
to 20 mA.