9-4SectionUser-defined Errors
135
9-4 User-defined Errors
There are two instructions that the user can use to define errors or messages.
These instructions can be used to generate warnings (non-fatal errors where the
ERC flashes) or errors (fatal errors where the ERC lights.
FAL(06) is an instruction that causes a non-fatal error. The following will occur
when an FAL(06) instruction is executed:
1, 2, 3... 1. The ERC indicator on the Customizable Counter Unit will flash. Operation
will continue.
2. The instructions 2-digit BCD FAL number (01 to 99) will be written to
SR 23500 to SR 23507.
3. The FAL number will be recorded in the error log area in the Customizable
Counter Unit. The time of occurrence will also be recorded.
The FAL numbers can be set arbitrarily to indicate particular conditions. The
same number cannot be used as both an FAL number and an FALS number.
To clear an FAL error, correct the cause of the error, execute FAL 00, and then
clear the error using the Programming Console.
FALS(07) is an instruction that causes a fatal error. The following will occur when
an FALS(07) instruction is executed:
1, 2, 3... 1. Program execution will be stopped.
2. The ERC indicator on the Customizable Counter Unit will light.
3. The instructions 2-digit BCD FALS number (01 to 99) will be written to
SR 23500 to SR 23507.
4. The FALS number will be recorded in the error log area in the Customizable
Counter Unit. The time of occurrence will also be recorded.
The FALS numbers can be set arbitrarily to indicate particular conditions. The
same number cannot be used as both an FAL number and an FALS number.
To clear an FALS error, switch the PC to PROGRAM Mode, correct the cause of
the error, and then clear the error using the Programming Console.
FAILURE ALARM FAL(06)
SEVERE FAILURE ALARM
FALS(07)

Table of Contents

Other manuals for Omron SYSMAC CS1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CS1 and is the answer not in the manual?

Omron SYSMAC CS1 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CS1
CategoryController
LanguageEnglish

Related product manuals