3-4SectionProgramming Devices
36
CX-Programmer Ver. 1.2 or later (register the PC model as a CQM1H-CPU61.)
Note 1. The Customizable Counter Unit cannot be used with CX-Programmer Ver.
1.1 or earlier.
2. The SYSMAC-CPT or SYSMAC Support Software cannot be used.
The functions available when using a Programming Device with the Customiz-
able Counter Unit are the same as when using one with a CPU Unit with the fol-
lowing exceptions.
PC Setup functions
Reading the error log
PC clock
Forced set/reset of the PC
Data trace
Reading the cycle time
PC information display
Note Before using the CX-Programmer, refer to the appendix, Precautions in Using
the CX-Programmer.
The following settings are required when using a Programming Device.
Programming Device Connection Switch
You must turn ON the Programming Device connection switch on the front of the
Unit before connecting a Programming Device to the peripheral port. It will not be
possible to connect to the Programming Device if this switch is turned OFF. (Turn
OFF this switch, however, to prevent malfunctions due to operational errors.)
Programming Device connection
switch
Programming Device
Set to ON:
TOOL
ON OFF
Connection enabled
(The switch must be turned ON to use a
Programming Device.)
Set to OFF:
TOOL ON OFF
Connection disabled
(Turn OFF the switch to prevent
operational errors.)
Unit Setup Area
When connecting a Programming Device to the peripheral port, depending on
the type of Programming Device, the serial communications mode, and commu-
nications conditions used, the Unit Setup Area (DM 6650 to DM 6651) settings
may or may not be necessary. This is shown in the following table.
Programming Device Serial
communications
mode (recognized
by Unit)
Communications
conditions
Unit Setup Area
(DM 6650 to
DM 6651)
Setting in
CX-Programmer
Programming Console (Programming
Console bus)
--- Settings not required ---
CX-Programmer Peripheral bus
9,600 bps Settings not required
Set to the same
ii
g
Other than above Set in DM 6650 to
DM 6651 (baud rate
only)
communications
conditions.
3-4-1 Programming Consoles
The following three Programming Console are available:
CQM1H-PRO01
CQM1-PRO01
C200H-PRO27
Functions Supported by
Programming Devices
Settings

Table of Contents

Other manuals for Omron SYSMAC CS1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CS1 and is the answer not in the manual?

Omron SYSMAC CS1 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CS1
CategoryController
LanguageEnglish

Related product manuals