4-1SectionOverview
44
Note n = 2000 + (unit number × 10) in the CPU Unit
Customizable Counter Unit
CPU Unit
General-pur-
pose words
Exchanged
cyclically
Words allocated in CIO Area
SR Area
230
231
234
235
236
239
n
n+1
n+4
n+5
n+6
n+9
to
to
Status
General-pur-
pose words
Commands
to
to
General-pur-
pose words
Status
General-pur-
pose words
Commands
4-1-3 Data Exchange Using the Words Allocated in DM Area
The data exchanged using the words allocated in DM Area consists of two types
of data.
1, 2, 3... 1. At startup or Unit restart, the Customizable Counter Units initial settings
(e.g., the startup operating mode) are transferred from the CPU Units DM
Area words m to m+9.
2. General-purpose data is exchanged cyclically between the DM Area words
m+10 to m+99 and the user-set words (e.g., in the DM Area or CIO Area) in
the Customizable Counter Unit.
Note m = D20000 + (unit number × 100) in the CPU Unit
Customizable Counter Unit
CPU Unit
Words allocated in DM Area
General-pur-
pose output
words
General-pur-
pose input
words
First input
word
Unit Setup Area
User-
defined
address
User-set words
General-pur-
pose words
m
m+9
m+10
m+99
User-
defined
address
User-set words
General-pur-
pose words
Initial settings
to
to
to
Initial settings

Table of Contents

Other manuals for Omron SYSMAC CS1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Omron SYSMAC CS1 and is the answer not in the manual?

Omron SYSMAC CS1 Specifications

General IconGeneral
BrandOmron
ModelSYSMAC CS1
CategoryController
LanguageEnglish

Related product manuals