OPTICON Universal menu book
U119
5.4. Redundancy
This is the number of times that a label must be
correctly decoded before it is transmitted.
Selecting a higher redundancy count makes
reading slower, but it reduces the probability of
reading errors, especially when labels of poor
definition are used.
SET
_ZZ_
Read 1 time,
redundancy = 0
X0
_X0_
Read 2 times,
redundancy = 1
X1
_X1_
Read 3 times,
redundancy = 2
X2
_X2_
Read 4 times,
redundancy = 3
X3
_X3_
END
_ZZ_