Page #78 background image
Code options
3
OPTICON Universal menu book
U71
3.3.14. Options for Korean Postal Authority
code
Korean Postal Authority code is a fixed length
numeric symbology with a mandatory check
digit. The check digit is not transmitted.
For string format see figure 3.36.
Options for Korean Postal Authority code:
transmit dash
not transmit dash
transmit CD
not transmit CD
Transmit dash:
The dash character '-' ( hex 2D ) is printed
between the 3rd and 4th digit
Fig. 3.36. Options for
Korean Postal Authority code
check digit data
(3 digits)
data
(3 digits)
Korean Postal Authority code
dash
(-)
SET
_ZZ_
Not transmit CD
*-
_*-_
Transmit CD
*+
_*+_
Not transmit dash
*/
_*/_
Transmit dash
*.
_*._
END
_ZZ_