IG-150-EN version 04; 03/10/16
8
General description General instructions
ekor.rps
Model coding:
MODELO PL300
MODEL
NB
NC
ND
NE
DB
DC
DD
DE
DF
IB
IC
BOX TYPE
TCP integrated Note 5
POWER SUPPLY
YdcV 06-81
ZdcV 082-68
ANALOG INPUTS TERMINALS
Pin type Standard terminals
Closed terminals
EXTENSION MODULE
No module
9 Dls (6 indepen.) + 7 DOs (3 indepen.)
DIGITAL INPUTS VOLTAGE
REAR COMMUNICATION PORTS
AGFO
BPFO
C RS232
DRS485
E GFO (COM-2) + GFO (COM-1)
IGFO (COM-2) + RS232 (COM-1)
JEthernet RJ45 + GFO (COM-2)
KEthernet GFO + GFO (COM-2)
LEthernet RJ45 + RS232 (COM-2)
MEthernet RJ45 + RS485 (COM-2)
TInternal communication for TCP
F
G
H
PFO (COM-2) + PFO (COM-1)
RS232 (COM-2) + RS232 (COM-1)
RS485 (COM-2) + RS232 (COM-1)
SPECIAL FUNCTIONS AND AUTOMATISMS
0 No Functions
179 + 79 (81 m) (Included in models IB, IC y CR)
285 (Only for directional PL-300 models)
379 + 79 (81 m) + 85 (Only for directional PL-300 models)
Battery voltage measurement and optional operating temperature
0None
1Battery voltage measurement
2
3
Optional operating temperature
Battery voltage measurement and optional operating temp.
Current polarized 67N
No 0
Yes 1
V0 or IN calculation
None 0
1
V
0 calculated
2
I
N calculated
Both (only for models DD + current polarized 67N,
DE + current polarized 67N, DF + current polarized 67N)
3
Programmable Protocol
Programmable Protocol
Programmable Protocol
Programmable Protocol
Note 1
Note 1
Note 1
Note 1
Note 1
Note 6
Note 6
Note 6
Note 6
Note 5
Note 2
Note 2
Note 3
no direccional
direccional
interconexión
centros de reparto
Note 4
Note 3
ekor.rps
ekor.rps non directional
ekor.rps Directional
ekor.rps Interconnection
T
H
Horizontal
1
2
0
1
Range: 18-160 Vdc
Y
Range: 86-280 Vdc
Z
CR
ekor.rps
Distribution center
Figure 1.1. Model coding
For models with two communication ports,
COM 2 port protocol is programmable, and
COM 1 protocol is always PROCOME.
79 (81 m) (recloser by underfrequency) unit,
only exist for models with 81 U
For the models marked with an * in the
transformer arrangement table
Only for models with 67 N and T9 = Ip
(*olarization current)
With T type box, the communication must
be “T
In this case, the Ethernet port protocol is
encapsulated PROCOME