_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
IDEA
vacuum packing machines
Pag. 26 a 76
8.2 Functions AND WARNINGS
8.2.1 Maximum admissible values
FUNCTION VALUE
VACUUM 10% ÷ 99%
ADDITIONAL VACUUM 0 ÷ 60 sec
GAS INJECTION 0 ÷ 90%
SEALING 0 ÷ 6 sec
SOFTAIR 0 ÷ 30 sec
PAUSE TIME (DEGAS CYCLE) 0 ÷ 60 sec
N°
DESCRIPTION
1
2
Set up the date (dd/mm/yyyy)
3
Display brightness regulation
4
Select the temperature measuring unit
5
6
7
Return to the previous screen, without saving the modified value
8
Save the programmed value and return to the previous screen
Settings
ENGLISH
Brightness
Temperature
_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
IDEA
vacuum packing machines
Pag. 27 a 76
CAUTION!
It is necessary to carry out preliminary tests, to identify the optimal percentage of GAS to be
injected, for every single product to be packed.
8.2.2 Factory configuration
FUNCTION VALUE
VACUUM 99%
ADDITIONAL VACUUM 0 sec
GAS INJECTION 0%
SEALING 2,5 sec
SOFTAIR 0 sec
9
how to operate with idea 32
Hi-Line
– 42
Hi-Line
9.1 ICONS AND PICTOGRAMS
ICON OR
PICTOGRAM
DESCRIPTION
Allows to exit the stand-by and turn the machine on
Displays the information – if present – about the screen
To access the Technical menu
USER CYCLES: Access to editable programs. The user can set the vacuum level,
additional vacuum, gas injected, sealing and softair
USER CYCLES: Access to Preservation preset cycle. To be used for storage of raw or
cooked products, solids or liquids not sensitive to crushing
USER CYCLES: Access to Cooking preset cycle. To be used to vacuum pack – in
vacuum cooking bags - all product to be cooked in sous-vide
USER CYCLES: Access to Vacuum + Gas Min preset cycle. To be used to vacuum pack
products to be protected from crushing, thanks to 30% injection of GAS