_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
IDEA
vacuum packing machines
Pag. 38 a 76
9.3.2 Chef programs operated in containers (Mussel cleaning, Marinade in containers, Pastry
bases, Ice cream bases, Meat tenderizing)
Phase
Description Image
1
Choose a container suitable for vacuum
packaging that fits in the vacuum chamber,
which remains approximately 1 cm from the
packaging machine lid once closed.
Fill the container with foodstuff and leave it
without lid.
Filling limits:
• Solid products: 100%
• Broths, infusions: 1/2
• Vegetarian and meat sauces: 1/3
• Creams, cream-based sauces: 1/4
• Egg products or egg white: 1/6
Insert products cooled to +3°C to achieve
the best result.
In case the product need to be STORED and PRESEREVERD or COOKED after the Chef Cycle, complete the process
vacuum packing it.
Theproduct must remain cooled at +3°C at all stages
2
Lift the lid to limit switch and clip the piston,
pulling it forward.
3
Open the lid and make sure the vacuum
chamber and product to be packaged are
dry.
Place the maximum number of black plates
(A) the vacuum chamber can contain,
according to the size of the product to be
packed.
_______________________________________________________________________________________
ORVED S.P.A Rev.01 – 09/2019 – cod. 1500735-00EN – User Manual for
IDEA
vacuum packing machines
Pag. 39 a 76
4
Choose a container suitable for vacuum
packaging that fits in the vacuum chamber
and remains at least 1 cm apart from the lid
closed.
It is possible to remove the sealing bar, if
necessary.
Make sure that the air intake device be open.
5
Activate the command panel by double
quick touch on the screen.
Press the STAND-BY button, to turn the
machine on.
6
Select Chef Cycles
7
Select the desired Chef program (Example:
Mussels cleaning)
8
Lower the lid using both hands, by pressing on
the corners.
The vacuum cycle starts automatically.
9
Pressing STOP button at any time, it is possible
to interrupt the vacuum cycle immediately
and the vacuum chamber is uncompressed.
The lid opens automatically.
The machine comes back to the selected
program.
10
End of cycle. The lid opens automatically. Remove the container.
Mussels cleaning